ISOKERN B-VENT FIREPLACE
A PRODUCT OF EARTHCORE INDUSTRIES, LLC.
INSTALLATION, OPERATION, MAINTENANCE and
OWNER’S MANUAL
ISOKERN MODELS IBV-36 and IBV-46
IMPORTANT: This manual contains assembly rules, installation steps and guidelines, and use and maintenance
instructions for Isokern B-VENT gas appliances (IBV). This manual must become the property of and be reviewed
by all current and future users of this product. It is the responsibility of the distributor, general contractor and the
installer of this product that the instructions in this manual are followed exactly and, further that the allowed gas
log appliance used in this product be installed in strict accordance with the gas log manufacturers listing and
explicit installation and operation instructions.
This Listed Top Vented Gas Log Enclosure is designed for use with
Decorative Natural Gas or Propane (LP) Gas Appliances, only.
DO NOT BUILD A WOOD FIRE
WARNING: If the information in this
manual is not followed exactly, a re or
explosion may result causing property
damage, personal injury or loss of life.
- NOT FOR USE WITH SOLID FUEL.
- The ue damper must be in the full open
position when burning the gas logs.
- Do not store or use gasoline or any other ammable
vapors or liquids in the vicinity of this or any other
appliance.
-This appliance complies with National Safety
and is tested and listed to ANSI Z21.50b - 2009 as
vented gas replaces.
- Installation and service must be performed
by a locally certied gas service agent, licensed
plumber or the gas supplier.
-Installation must conform to local codes. Check
local codes prior to installation.
In the absence of local codes, installation must
conform with current National Fuel Gas Code,
ANSI Z223.1.
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for future
reference.
- WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electrical switch.
* Do not use any phone in your building.
* Immediately call your gas supplier
from a neighbor’s phone. Follow the gas
supplier’sinstructions.
* If you cannot reach your gas supplier,
call the re department.
PFS Report No. 09-79
SAP No. 506022-03
Issued: March, 2014
Revision: 004
© 2009 ECI
THIS MANUAL CAN ONLY BE REPRODUCED IN ITS ENTIRETY
USA: ANSI Z21.50b-2009b-2009
Canadian: CSA 2.22b - 2009
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - Canadian: CSA 2.22b - 2009

ISOKERN B-VENT FIREPLACEA PRODUCT OF EARTHCORE INDUSTRIES, LLC.INSTALLATION, OPERATION, MAINTENANCE andOWNER’S MANUALISOKERN MODELS IBV-36 and IBV-46I

Seite 2 - Table of Contents

10Combustible Floor System LoadingImportant: Floor framing for IBV installation will need tobe designed and built to accept substantial dead loads spr

Seite 3 - General Information

11IBV Rough Framing DimensionsRough Framing DimensionsModel A B CIBV 36 43” 72”,83”,93” 26 3/4”IBV 46 53” 72”,83”,93” 26 3/

Seite 4 - Safety Information

12IBV Assembly InstructionsGeneral Assembly Instructions: Earthcore Mortar (a thin-set type masonry adhesive) is used to glue all IBV masonry compone

Seite 5

Raised hearthfor wood orconcrete installsFlush Hearthon ConcreteFoundations OnlyEarthcoreMortar13IBV Assembly Instructions (cont.)Assembly Steps for I

Seite 6 - Plan View

Drill HoleEarthcoreMortarEarthcore MortarFirst CourseBack WallTop CourseBack WallEarthcore MortarHigh TemperatureWire ( 2 pc. / 12’ long)High Temperat

Seite 7

15IBV Assembly Instructions (cont.)Step 5: Once all the rebox wall components are set check the top surface of the rebox for level.Step 6: Begin the

Seite 8 - Required Component List

FirebricksideGas or electriclineNOTE: Fill any gaps aroundline with Earthcore MortarFlex duct to fireplacefirebox (all parts non-combustible)Exterior wa

Seite 9

17IBV Assembly Instructions (cont.)Fire Brick Installation:The manufacturer requires that the replace reboxes be lined with a minimum one and one-ei

Seite 10 - Figure 1

High TemperatureLimit Switch2 High TemperatureWiresTab to be bent upwardto stand vertical(both sides)18IBV Assembly Instructions (cont.)Metal Canopy I

Seite 11 - IBV Corner Location Layout

19Venting InstallationAnchor Plate/ Damper Installation: Cut a twelve inch (12”) diameter hole in the center of the ceramic ber blanket which is the

Seite 12 - IBV Assembly Instructions

Table of Contents2General Information ...

Seite 13 - Figure 6

20Venting Installation (cont.)The IBV, per ANSI-Z21.50 standard, requires double wall, gas only B-Vent metal piping for the purpose of venting the app

Seite 14 - Figure 7

21Venting Installation (cont.)Mechanical Vent Systems:It is acceptable to use mechanical draft systems, if the venting companies do the engineering ca

Seite 15 - Figure 12

22Flush Wall Finish DetailIBVs are designed to be installed so that the rough front face of the Isokern rebox and smoke dome sit ush to the room fac

Seite 16 - Figure 15

8“ min. Finished Opening8“ min.Wood (Flammable)Sheathing8” min8” min 8” minFront ofFirebox reference23Combustible wood sheathing such as plywood and p

Seite 17 - Gas Fuel Only

24Flush Wall Fire Brick Finish DetailRecommended Fire Brick Detail: With drywall crossing over the face of the IBV smoke dome assembly (as previously

Seite 18 - Terminals

25Important: Since there is no re brick set along the top of the IBV rebox opening, when setting the noncombustible facing material (code required a

Seite 19 - Venting Installation

26Interior Full Masonry Veneer Finished Fireplace FrontsIsokern unit width dimensionExtent of Steel L4” Bearing3 ½” minimumclearanceSteel LWood (Flamm

Seite 20 - Venting Installation (cont.)

Masonry VeneerWood (flammable)Sheathing4” 2” min.Min. clearanceMin. clearance8” min.Steel L27Interior Full Masonry Veneer Finished Fireplace Front Deta

Seite 21

CombustibleFloor System(non-flammable)CombustibleFloor System(non-flammable)Ceiling42”minimum clearancefrom openingto ceilingHearthExtension(non-combust

Seite 22 - Flush Wall Finish Detail

29ISO-FLAMES Gas Log Burner InstallationThe gas control valve is installed on the right side of the ISOFLAMES gas log burner. If the gas supply line c

Seite 23 - Required Clearances

3General Information IBV Models IBV-36 and IBV-46 are tested and listed by PFS Corp., USA Report No. 09-79 to ANSI Z21.50b-2009b-2009 and Canadian St

Seite 24 - Figure 28

30ISOFLAMES® Gas Log SystemOWNER’S MANUALInstallation & Operating InstructionsISOFLAMES Gas Log Systems24” - 30”THE ISOFLAMES GAS LOG SYSTEM MUST

Seite 25 - Finish Facing Detail

31General InformationTools Required:1. Adjustable wrench2. 3/8” aring tool3. Open-end wrench (7/16”)4. Open-end wrench (3/4”)5. Pipe thread sealer (N

Seite 26 - Figure 31

32Safety Instructions Prior To Installation/Pilot Assembly Wire DiagramISOFLAMES FIREPLACE WIDTH FIREPLACE HEIGHT BTU NATURAL GAS BTU LIQUID BU

Seite 27 - Figure 33

33Isoames Gas Log Burner InstallationIsokern Gas Burner Installation InstructionsFig. 1 - Burner System Detail - Bottom View1. MAKE SURE THE FIREPL

Seite 28

34Isokern Gas Burner Installation InstructionsFig. 4 - Connect gas supply7. LEAK TEST: Tu rn on the fi replace gas supply, and test at all co

Seite 29 - GAS SUPPLY

35ISOFLAMES Gas Log Assembly InstructionsImportant: Although there is some fl exibility with the log placement, adequate spacing between the logs i

Seite 30 - WARNINGS

36Fig. 2-21Fig. 2-3Fig. 2-1Note: Highlighting added to improve clarity.12846357LOG PLACEMENTEach log in this gas log set is numbered here to assist i

Seite 31

FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING: If you do not follow these Instructions exactly, a re or explosion may result causing property damage,

Seite 32

38Lighting Instructions (cont.)Important: The ISOFLAMES Series gas log system must be installed by a liscensed plumber or gas tter per code.WARNING:

Seite 33

39Maintenance:The ISOFLAMES gas log system will last a lifetime, but periodic maintenance (at least once a year) is recommended. Can you clean it your

Seite 34

4Safety InformationWARNING: This product contains or generates chemicals known to the state of California to cause cancer or birth defects or other r

Seite 35

40ISOFLAMES Customer Service & WarrantyCustomer ServiceEarthcore Industries, LLC is committed to customer service and exceeding customer expectati

Seite 36

41Warranty CardPlease cut along dashed lines and send to:Earthcore Industries, LLC6899 Phillips Industrial Blvd.Jacksonville, Fl 32256Attn: Technical

Seite 37 - FOR YOUR SAFETY

1REV 1 - 0909221329OPTIONAL ISOFLAME WALL SWITCH INSTRUCTIONSFig. 1 - Connect wall switch to remote receiver boxInstallation1. Install the wall switc

Seite 39

Warranty & DisclaimerIsokern Fireplace Earthcore offers a lifetime warranty for all Isokern components, to be free from defects in materials that

Seite 40

5Safety Information17. Wherever insulation is used, the replace must not be placed directly against it. Keep all insulation and vapor barrie

Seite 41 - Warranty Card

6Assembled Firebox & Smoke Dome DimensionsEarthcore Industries, LLC. reserves the right to make changes at any time, without notice, in design, ma

Seite 42 - REV 1 - 0909221329

7Component List & DimensionsPartNo.:2123FireplaceSize:36” W46” WQuantity:11PartNo.:12FireplaceSize:36” WQuantity:2PartNo.:1111FireplaceSize:36” W4

Seite 43

8Required Component ListIn addition to the standard IBV modular masonry rebox and smoke dome assembly components the IBV requires particular componen

Seite 44 - Warranty & Disclaimer

9Required Clearance to CombustiblesImportant: “Combustibles” are dened as “normal construction materials” and considered to be: wood framing material